What was found
CORROSION ON FWD ENTRY DOOR MOP SILL; BS 294.3+8; LBL 60; WL 208.<[01] VERIFIED APPLICABILITY OF SRM 53-10-15-1A-1-A00051 ALLOWABLE DAMAGE (PERMANENT (NON-DENT DAMAGE TYPES));[02] REMOVED CORROSION ON FWD ENTRY DOOR MOP SILL IAW SRM 51-10-02-0G-0 L=3.680'' X W=1.740'' X D=0.020'' ORIGINAL THICKNESS=0.090''. EVALUATED BLENDED AREA AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-1 PART 4.C(2) FIG.108 DETAIL D. TOOL USED CALIPER ID: ATS2500 CAL DUE DATE:04/2024; MICROMETER ATS2826 CAL DUE DATE:01/2024.;[03] PART REPLACEMENT IS DOCUMENTED ON CUSTOMER CARD# TTG8Q00KN9BV.;[04] VERIFIED CORRECTIVE ACTION 1; 2 AND 3