What was found
FWD CARGO L/H SIDEPLATE HAS PUNCTURE WITH CRACK AT LBL 24; STA. 500C +13'<[01] PUNCTURE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-00-53-1A-2.;[02] CUT AND REMOVED THE DAMAGED TRANSITION ANGLE FRO STA 450 TO STA 500I L/H PER SRM 53-00-53-2R-5.;[03] LOCATED AND DRILLED REPAIR PARTS FROM STA 440+10 - STA 500I I.A.W SRM 53-00-53-2R-5.;[04] LOCATED AND DRILLED REPAIR PARTS FROM STA 440+10 - STA 500I I.A.W SRM 53-00-53-2R-5.;[05] FWD CARGO L/H SIDE PLATE FROM STA 440+10 TO STA 500I REPLACED ON FAULT TTG8Q00KSRV.;[06] CORRECTIVE ACTION #5 ENTERED INCORRECTLY. FWD CARGO L/H SIDE PLATE FROM STA 440+10 TO STA 500I REPLACED ON FAULT TTG8Q00KTSRV.;[07] INSPECTED WORK PERFORMED