What was found
EMERGENCY LIGHT EXIT INDICATOR L1189 INOP<[01] PERFORMED TROOBLESHOOT EMERGENCY LIGHT L1189 INOP; PERFORMED POWER AND GROUND CHECK PER WDM 33-51-21; GND RINGOUT GOOD; POWER WIRE W3142-0212-20 READ OPEN; FOUND WIRE W3142-0212020 CUTTED; REPAIR WIRE PER SWPM 20-30-12; PERFORMED GOOD FUNCTIONAL TEST OF EMERGENCY LIGHT L1189 PER AMM 33-51-00-710-801.<BR>SPLICE CRIMPERS ID <BR>ISOOO351<BR>S/N UNKNOWN<BR>DUE DATE 10/2023;[02] VERIFIED CORRECTIVE ACTION #1