What was found
AFT CARGO L/H SIDEPLATE HAS CORROSION AT FASTENER HOLES LBL 21; STA. 727I-727J<[01] REMOVED CORROSION AFT CARGO L/H SIDEPLATE AT FASTENER HOLES LBL 21; STA. 727I-727J FOUND OUT OF LIMIT CUT OUT SECTION OF L/H TRANSITION ANGLE BS 727G +10 -747 +12 PER SRM 53-00-53-2R;[02] C/W INSPECTION.;[03] FABBED ; LOCATED ; DRILLED ; TREATED AND PRIMED REPLACEMENT TRANSITION ANGLE AND SPLICE (REPAIR PARTS) PER SRM 53-00-53-2R-5;[04] INSTALLED CLICKBOND NUT PLATES ON 4 MAY 2023 AT 12:21PM;[05] C/W INSPECTION.;[06] OK TO INSTALL TRANSITION ANGLE.;[07] INSTALLED 2EA FABRICATED SPLICES AND REPLACEMENT TRANSITION ANGLE BETWEEN SPLICES LEFT TRANSITION ANGLE FROM STA 727G +10 TO 747 +12 PER SRM 53-00-53-2R-5.;[08] RII: INSPECTED WORK ACCOMPLISHED IN C/A #7. RICHARD PARRY (TECHNICIAN); 05-MAY-2023 06:35 UTC INSTALLED 2EA FABRICATED SPLICES AND REPLACEMENT TRANSITION ANGLE BETWEEN SPLICES LEFT TRANSITION ANGLE FROM STA 727G +10 TO 747 +12 PER SRM 53-00-53-2R-5.;[09] UPDATED FROM MINOR TO MAJOR REPAIR TYPE;[10] REPAIRED L/H SIDE PLATE LBL 21 FROM STA 727G+10 TO 747+12 PER SRM 53-00-53-2R-5.;[11] THOMAS BAUER (TECHNICIAN); 09-MAY-2023 15:20 UTC<BR>REPAIRED L/H SIDE PLATE LBL 21 FROM STA 727G+10 TO 747+12 PER SRM 53-00-53-2R-5. INSP. C/W