What was found
MULTIPLE AREAS OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727B-767 WL 154-155.<[01] REMOVED CORROSION MULTIPLES AREAS ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727B TO BS 767 WL 154-155; REWORKED AREA: L= 2.5' W= 1.2' D= 0.007' ORIGINAL THICKNESS 0.032' REMAINING MAT. 0.025' FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2;[02] VERIFIED CORRECTIVE ACTION ITEM 1; OUT OF LIMITS.;[03] LOCATED AND DRILLED AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727B-767 WL 154-155 PER B737-700 DWG 146A7502 REV A.;[04] UPDATED CORRECTIVE ACTION 3. LOCATED AND DRILLED AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727B-767 WL 154-155 PER B737-700 DWG 146A7502 REV A. SIDEWALL SUPPORT WILL BE INSTALL ON WORK CARD TTG8Q004A4L8.;[05] VERIFIED CORRECTIVE ACTION 4<BR><BR>VERIFIED MEASUREMENT TABLE