What was found
CORROSION FLOOR BEAM INTERCOSTAL LOCATED BETWEEN STA 294.5 AND STA 312 TO LBL 11.5 AND WL 208.1 AT FWD GALLEY AREA 2023-282626<[01] TOOL USED DIGITAL CALIPER P/N:500-196-30; S/N:A22046819; DUE DATE: 22/JUN/23;[02] REPLACED FLOOR BEAM INTERCOSTAL LOCATED BETWEEN STA 294.5 AND STA 312 TO LBL 11.5 AND WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG #141A5600 REV: N. SEE INDIVIDUAL SIGNS-OFF BELOW.;[03] REPLACED FLOOR BEAM INTERCOSTAL LOCATED BETWEEN STA 294.5 AND STA 312 TO LBL 11.5 AND WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG #141A5600 REV: N. SEE INDIVIDUAL SIGNS-OFF BELOW. RII