What was found
MAIN DISTRIBUTION BAY CRACK ON END OF STR 26L BS 540<[01] UPDATED MEASURING TABLE. REMOVED DAMAGED SECTION OF STRINGER 26L BS 500D+11'-540 IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4-B. PERFORMED GVI ON REPAIR AREA AND NO ADDITIONAL DAMAGED FOUND IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4-B(1). ACCOMPLISHED HFEC SURFACE SCAN OF CUT EDGE IAW NDTM PART 6 CHAPTER 51-00-00 PROCEDURE 23. NO CRACKS NOTED. RECEIVED NEW STRINGER SECTION S-26L FROM OSS RO. 917134-SWA-3 IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4D.;[09] VERIFIED CORRECTIVE ACTION ITEM 8.;[10] RECEIVED STRINGER SPLICE SECTION S-26L FROM OSS RO. 917134-SWA-1 IAW SRM 53-00-03-2R-1 REP. 1 PAR. 4D.