AFT CARGO COMPARTMENT BILGE AREA. SUPPORT ANGLE FOR WASTE TANK ENCLOSURE BEAM IS CRACKED. LOCATED AT STA 867 LBL 13; WL 161. MARKED. AFT CARGO COMPARTMENT BILGE AREA. SUPPORT ANGLE FOR WASTE TANK ENCLOSURE BEAM IS CRACKED. LOCATED AT STA 867 LBL 13 WL 161. MARKED.<[01] R&R CRACKED SUPPORT CLIP PER SRM 51-40-05 AND SRM 51.40.02;[02] C/W INSPECTION