What was found
CRACK INSPAR RIB 5 STA129.50 LOCATED AT 2ND VERTICAL STIFFENER AT LT HORIZONTAL STABILIZER 2023-282678<[01] EDDY CURRENT EQUIPMENT USED P/N: NORTEC 600D; S/N: 200053402 AND DUE DATE: 13-MAY-23.;[02] EDDY CURRENT EQUIPMENT P/N: NORTEC500D; S/N: N500X12101V022237; DUE DATE: 26-JAN-24.;[03] RII STEP COMPLETED;[04] PERFORMED PERMANENT REPAIR ON INSPAR RIB 5 STA129.50 LOCATED AT 2ND VERTICAL STIFFENER AT LT HORIZONTAL STABILIZER I.A.W B737-700 SRM 55-10-09-2R-5; FIGURE 204; SHEET 1.<BR>SEE INDIVIDUAL SIGNOFFS BELOW.;[05] PERFORMED PERMANENT REPAIR ON INSPAR RIB 5 STA129.50 LOCATED AT 2ND VERTICAL STIFFENER AT LT HORIZONTAL STABILIZER I.A.W B737-700 SRM 55-10-09-2R-5; FIGURE 204; SHEET 1. <BR>SEE INDIVIDUAL SIGNOFFS BELOW. COMPLETE TASK CERTIFIED RII