What was found
CRACKED FLOOR SUPPORT AT STA 540; RBL 1; WL 207.8<[01] NO DAMAGE LIMITS GIVEN IN SRM; PART HAS MULTIPLE CRACKS; PART IS REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9; REMOVED CRACK DAMAGED BREAK PANEL FROM BS 540 RBL 1 TO RBL 23 WL 206.5 IAW SRM 51-40-02-0G-0; LOCATED AND DRILLED NEW BREAK PANEL IAW SRM 51-40-05-0G-0 OK TO INSTALL;[02] OK TO INSTALL.;[03] INSTALLED NEW BREAK PANEL AT BS 540 RBL 1 TO RBL 23 WL 206.5 IAW SRM 51-40-02-0G-0 AND AIPC 53-31-00-05;[04] RII; VERIFIED CORRECTIVE ACTION 3.;[05] VERIFIED MEASUREMENT TABLE; TASK IS COMPLETE.