What was found
DOT 114-015. CABIN FLOOR BOARD 242AF HAS AREAS OF PULLED FIBER.<[01] EVALUATED PANEL 242AF AND FOUND AREA OF PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR 1A. CLEAN AND PREP. IAW B737-700 SRM 53-00-50-2R-1 PAR 3A;E E&F. VERIFY MATERIALS AS: BMS 8-201 (A176813); BMS 9-3 (A164924). IAW B737-700 SRM 53-00-50-2R-1 TABLE 201. NEED OK TO BOND.;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR. IAW B737-700 SRM 53-00-50-2R-1 PAR 3K-M.;[04] REPAIRED DAMAGE TO UPPER SURFACE ON PANEL 242AF. IAW B737-700 SRM 53-00-50-2R-1; SRM 53-00-50-2R-0.;[05] VERIFIED STEPS 3-4