What was found
FWD FLOOR PANEL 221BF O/B TANG IS CRACKED.<[01] IDENTIFIED PANEL 221BF IAW SRM 53-00-50-0I-1 FIG 2; TABLE 2 FOUND CRACKE ALONG BOTH UPPER AND LOWER SKINS OF TANG TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F.<BR><BR>COMPLETELY REMOVED TANG; PREPED AREA AND CLEANED IAW SRM 53-00-50-2R-6 PARA 3. A. AND 3.C. - 3. E. WITH NO WATER OR CONTAMINATION NOTED.<BR><BR>REPAIR TO BE ACCOMPLISHED IAW SRM 53-00-50-2R-6.<BR><BR>OK TO INSTALL AND POT CORE FOR NEW TANG.[03] FABRICATED REPAIR PLIES AND CORE PLUG FROM REPAIR FABRIC BMS 9-3 TY H2 ST 1581 LOT#1522395-2 AND CORE BMS 8-124 TY5 GR5 CL4 LOT# 1283769 IAW SRM 53-00-50-2R-6 PARA 3. F.- G. (1) (A).;06] INSTALLED CORE PLUG TO REPAIR AREA USING BMS5-28 TY19 LOT# AK2LP8414K AND INSTALLED UPPER SURFACE PLIES USING BMS8-201 TY IV EPOCAST 50-A (946) LOT# 1526722-1; SET UP VACUUM BAG SYSTEM WITH BLEED DOWN TEST CHECKED GOOD AND NO LEAKS USING GAUGE ID: ATS2798 CAL/DUE: 10/2023 IAW SRM 53-00-50-2R-6 PAR. 3. G. (1) (B) & 3. G. (1) (C) & 3. H. (1)[10] FABRICATED LOWER SURFACE REPAIR PLIES FROM BMS9-3H2ST1581 LOT#1522395-2; OK TO INSTALL IAW SRM 53-00-50-2R-6 PARA 3K(1).[12] INSTALLED REPAIR PLIES USING BMS8-201 TYPE 4 LOT#1526722-1; VACUUM BAGGED; CHECKED FOR LEAKS; LEAK CHECKED GOOD USING VACUUM GAUGE ATS2441 CAL DUE DATE 08/2023 AND SET FOR CURE USING HEAT LAMP AND THERMOMETER ATS2208 CAL DUE DATE 10/2023 IAW SRM 53-00-50-2R-6 PARA 3K(1)-L(1)-M(1).