What was found
MULTIPLE AREAS OF CORROSION ON AFT CARGO BAY FWD DOOR SHIELD AT RBL 21 BS 767-787+5 WL 155.<[01] NO ALLOWABLE DAMAGE LIMITS IN SRM. REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PARAGRAPH # 9;[02] VERIFIED CORRECTION ACTION ITEM 1.;[03] RECEIVED NEW SHIELD P/N 146A8127-12; LOT: 1524920-2<BR>LOCATED AND DRILLED BETWEEN AT RBL 21<BR>BS 767 BS 787+5 WL 155<BR>IAW SRM 51-40-05 AND DWG: 146A0081<BR>OK TO TOP COAT;[04] VERIFIED CORRECTIVE ACTION 3.<BR>OK TO TOPCOAT APPLICATION.;[05] VERIFIED MEASUREMENT TABLE;[06] APPLIED TOPCOAT ON SHIELD <BR>IAW CUSTOMER CARD # M-22-125-02598 AND AMM 51-21-73<BR>04-MAY-2023 16:26 UTC OK TO CIC.;[07] REMOVED FROM ACB FWD SHIELD <BR>AT RBL21 BS 767 BS 787+5 WL 156<BR>IAW SRM 51-40-02.;[08] VERIFIED CORRECTIVE ACTIONS 6 AND 7.;[09] APPLIED CIC ON FWD SHIELD <BR>IAW CUSTOMER CARD # M-22-125-02598 AND SRM 51-20-01<BR>05-MAY-2023 18:45 UTC<BR>OK TO INSTALL;[10] VERIFIED CORRECTIVE ACTION 9;[11] FWD SHIELD OK TO INSTALL GIVEN;[12] INSTALLED ON ACB FWD SHIELD<BR>AT BS 767+8 BS 787+5 RBL21 WL 155<BR>IAW SRM 51-40-02 AND DWG 146A0081;[13] VERIFIED CORRECTIVE ACTION 12 AND MEASUREMENT TABLE