What was found
CORROSION ON FWD CARGO BAY DOOR CUT-OUT AFT SHIELD AT STA 500+10; 500+12.5 TO 500+15.5; AND 500+12; RBL 24 WL 156.<[01] FOUND TO BE OUT OF LIMITS PER B 737-700 SRM 53-30-15-1A-1;[02] B 737-700 SRM 53-30-15-1A-1 IS APPLICABLE REFERENCE;[03] VERIFIED CORRECTIVE ACTION 1-2 AND MEASUREMENT TABLE;[04] REMOVED SHIELD PER B737-700 SRM 51-40-02;[15] INSTALLED FWD CARGO BAY DOOR -OUT AFT SHIELD AT STA 480+14 TO 500A RBL 24 WL 156 IAW SRM 51-40-02 AND DWG 143A8126 REV;-;[16] VERIFIED CORRECTIVE ACTION STEP 15.;[17] VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.