What was found
LH VAPOR BARRIER PERVIOUS REPAIR IS CRACKED AT BODY STATION 666 FROM WL20 TO WL 24. LH VAPOR BARRIER PERVIOUS REPAIR IS CRACKED AT BODY STATION 663 FROM WL20 TO WL 24.<[01] IDENTIFIED PART AND MATERIAL IAW SRM 57-10-10-0I-2; FIGURES 1-2; TABLE 2; ITEM [4].<BR>FOUND DAMAGE TO PREVIOUS REPAIR TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 57-10-10-1A-2 PAR 4.D (1) (A) 1).<BR>A PERMANENT REPAIR WILL BE ACCOMPLISHED IAW SRM 51-70-04-2R-10 AS DIRECTED PER SRM 57-10-10-2R-2 PAR 1.C.;[02] VALIDATED REPAIR PER SRM 51-70-04-2R-10;