What was found
CORROSION ON FLOOR BEAM LOCATED BS 986.5 AT LEVEL STR 17R RBL 43 WL 208.1 AT AFT GALLEY AREA 2023-299421<[01] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DUE DATE: 31-JAN-24.;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DUE DATE: 31-JAN-24.;[03] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DUE DATE: 31-JAN-24.;[04] REPLACED T-CHORD LOCATED ON FLOOR BEAM LOCATED BS 986.5 AT LEVEL STR 17R RBL 43 WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-4; EA NO:1-753-35007 REV: IR;[05] CORRECTED STEP 4:<BR>REPLACED T-CHORD LOCATED ON FLOOR BEAM LOCATED BS 986.5 AT LEVEL STR 17R RBL 43 WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-4; EA NO:1-753-35007 REV: IR.<BR>SEE INDIVIDUAL SIGN OFF BELOW.;[06] REPLACED T-CHORD LOCATED ON FLOOR BEAM LOCATED BS 986.5 AT LEVEL STR 17R RBL 43 WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-4; EA NO:1-753-35007 REV: IR. RII. SEE INDIVIDUAL SIGN OFF BELOW.