What was found
MAIN CABIN FWD WET AREA CORROSION AT PANEL BREAK ANGLE BETWEEN STA 312-328 RBL 9'<[01] REMOVED CORROSION AT MAIN CABIN FWD WET AREA AT PANEL BREAK ANGLE BETWEEN STA 312-328 RBL 9' AS PER SRM 51-10-02-0G-0. FOUND OUT OF LIMITS AS PER SRM 53-10-51-1A-1. <BR>REMOVED & INSTALLED NEW ANGLE AT MAIN CABIN FWD WET AREA BETWEEN STA 312-328 RBL 9' AS PER SRM 51-40-02-0G-0 AND DWG 141A5400.;[02] VERIFIED STEP # 1