What was found
PASSENGER CABIN FLOOR PANEL 222CF HAS DELAMINATION ON PANEL<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>REMOVED 29EA INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3.B.<BR>REMOVED DAMAGED SKIN PLIES ON UPPER SURFACE; CLEANED REPAIR AREA AND FABRICATED REPAIR PLIES USING BMS 9-3H2 LOT#1522395-2 IAW SRM 53-00-50-2R-1 PARA 3.C;E-F AND K(1).;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1.;[03] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1 AND 2. <BR><BR>VERIFIED MEASUREMENTS TABLE.;[04] INSTALLED REPAIR PLIES USING BMS 8-201TY4 LOT#1527294-1; VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2441 CAL DUE 08/2023 IAW SRM 53-00-50-2R-1 PARA 3.K(1)-L(1).;[05] INSPECTED AND VERIFIED CORRECTIVE ACTION 4.;[06] CURED REPAIR USING THERMOMETER ID:ATS2208 CAL DUE 10/2023 IAW SRM 53-00-50-2R-1 PARA 3.M(1).;[07] UN-BAGGED; TRIMMED EXCESS MATERIAL; INSTALLED (29EA) THROUGH INSERTS USING BMS5-107 CL1 LOT#AK2KP8383K-1; AND CURED INSERTS UNDER HEAT LAMP USING THERMOMETER ID:ATS2208 DUE:10/2023 IAW SRM 53-00-50-2R-1 PAR.3 M(1) & N; AND BOEING DWG 141A5810-750<BR><BR>JOB COMPLETE;[08] VERIFIED CORRECTIVE ACTIONS 6 AND 7;[09] UPLOADED CURE SHEET. JOB COMPLETE;[10] FINAL INSPECTION. JOB COMPLETE.