What was found
FLOOR PANEL 221GF HAS A BROKEN TAB.<[01] IDENTIFIED FLOOR PANEL 221GF IAW SRM 53-00-50-0I-1 FIGURE 2 TABLE 2 <BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 F<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-6 <BR><BR>REMOVED (2EA) THROUGH INSERTS TO FACILITATE REPAIR<BR>REMOVED DAMAGE TO BOTH SKINS AND HONEYCOMB CORE MEASURING 2'X1'; CLEANED WITH NO CONTAMINATION NOTED IAW SRM 53-00-50-2R-6 PAR.3 A-E;[02] VALIDATED REPAIR PER SRM 53-00-50-2R-6;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE<BR><BR>VALIDATED REPAIR PER SRM 53-00-50-2R-6;[04] APPLIED POTTING BMS 5-28TY19 LOT#AK2LP8414K TO EXPOSED TO ACCOMMODATE CORE PLUG INSTALLATION IAW SRM 53-00-50-2R-6 PARA 3.F.;[05] DUE TO THE LACK OF REPAIR MATERIAL; REPLACED FLOOR PANEL 221GF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-51-21L ITEM 335.;[06] PANEL REPLACED. JOB COMPLETE.