What was found
CRACKED INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; LBL 13; WL 208.<[01] REMOVED DAMAGED INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; LBL 13; WL 208 IAW SRM 51-40-02-0G-0;[02] NO CRACK LIMITS FOUND ON SRM; PART REPLACEMENT IAW SRM 51-10-02-0G-0 PAR.9.;[03] RECEIVED; LOCATED; DRILLED; APPLIED CHEMICAL CONVERSION COATING AND PRIMER NEW INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; LBL 13; WL 208 RO #891113-SWA. IAW SRM 51-40-05-0G-0; DWG 143A5400.;[04] OK TO INSTALL.;[05] VERIFIED CORRECTION ACTION ITEM 2;3 AND 4; MEASUREMENT TABLE; OK TO INSTALL GIVEN.;[06] INSTALLED NEW INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; LBL 13; WL 208 IAW SRM 51-40-02-0G-0 AND DWG 143A5400.;[07] VERIFIED CORRECTIVE ACTION 6.