What was found
AFT CARGO FLOOR STRUCTURE: LEFT SIDE PLATE (TRANSITION ANGLE) HAS CORROSION AROUND THE FASTENER HOLES. LOCATED AT STA 727J +2; +6; +13 AND +14. MARKED. AFT CARGO FLOOR STRUCTURE: LEFT SIDE PLATE (TRANSITION ANGLE) HAS CORROSION AROUND THE FASTENER HOLES. LOCATED AT STA 727J +2 +6 +13 AND +14. MARKED.<[01] COMPLIED WITH TOOL REQUIREMENT.;[02] COMPLIED WITH MEASUREMENTS.;[03] REMOVED CORROSION FROM AREA PER SRM 53-00-53-1A-2 (REMAINING THICKNESS<BR>0.038'). SIDEPLATE (TRANSITION ANGLE) IS OUT LIMITS PER SRM 53-00-53-1A-2.;[19] INSTALLED LH SIDEPLATE (TRANSITION ANGLE) REPAIR PARTS FROM STA 727F+11' TO 787+9' PER SRM 53-00-53-2R-5.