What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT ACB BS767 - BS727A RBL21 WL158.<[01] VERIFY APPLICABILITY PER SRM 53-60-53-0I-2 AND SRM 53-00-53-1A-2<BR>REMOVED CORROSION ON DISCREPANCY AREA L=3.5'; W=1.7'; D=0.007'. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 STEPS 4A(2)(A) FIG 103 TOOL USED ID:ATS2827 ; DUE:01/2024;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] RECIVED NEW FLOOR TO SIDEWALL ITEM 146A7502-51 LOT 1519356/1 LOCATED AND DRILLED NEW FLOOR TO SIDEWALL AT BS 727 TO BS 767 WL 158; IAW 737-700 SRM 51-40-05-0G-0 DWG 146A7500.-;[04] VERIFIED CORRECTIVE ACTION 3;[05] VERIFIED MEASUREMENT TABLE;[06] UPDATE PART REQUIREMENT;[07] CARD COMPLETE