What was found
CORROSION ON STRINGER CLIP AT ACB BS787 S-26R RBL15.<[01] EVALUATED CORROSION DAMAGE ON STRINGER CLIP AT ACB BS 787; S-26R RBL15 FOUND TO BE OUT OF LIMITS DUE NOT LIMITS IN SRM PARTS WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0;[02] REMOVED STRINGER CLIP AT ACB BS787 S-26R RBL15 IAW SRM 51-40-02-0G-0;[03] OBTAINED NEW STRINGER CLIP AT ACB BS787 S-26R RBL15 P/N 146A1010-27 LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG # 166A1010 ; OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION ITEMS 1; 2; 3.<BR>OKAY TO INSTALL NEW STRINGER CLIP GIVEN.;[05] INSTALLED NEW STRINGER CLIP AT ACB BS787 S-26R RBL15 P/N 146A1010-27 IAW SRM 51-40-02 AND DWG 146A1262;[06] UPDATE MEASUREMENT TABLE;[07] VERIFIED MEASUREMENT TABLE;[08] VERIFIED CORRECTIVE ACTION 5