What was found
CORROSION ON CLIP AT ACB BS807 LBL7 WL154.<[01] EVALUATED CORROSION DAMAGE ON CLIP AT ACB BS 807; LBL7 WL 154 FOUND TO BE OUT OF LIMITS DUE NOT LIMITS IN SRM PARTS WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0;[02] REMOVED CLIP AT ACB BS 807 LBL7 WL 154 IAW SRM 51-40-02-0G-0;[03] FABRICATED A CLIP AT ACB BS807 LBL7 WL154 FROM BAC1490-2815#7075T62 CLAD LOT#1455934-1. TREATED IAW SRM 51-40-05 AND IAW DWG#146A1320. OK TO PRIME;[04] VERIFIED CORRECTIVE ACTION ITEMS 1; 2; 3.<BR>OKAY TO PRIME NEW CLIP GIVEN.;[05] APPLIED TWO LAYERS OF BMS 10-11; TYPE I PRIMER TO THE SURFACE OF NEW CLIP AT ACB BS 807 LBL7 WL 154 REFER TO SOPM 20-41-02.;[06] OK TO INSTALL;[07] VERIFIED CORRECTIVE ACTION 5 AND 6 OK TO INSTALL;[08] INSTALLED CLIP AT ACB BS807 LBL7 IAW SRM 51-40-02 AND IAW DWG#146A7810;[09] VERIFIED MEASUREMENT TABLE;[10] VERIFIED CORRECTIVE ACTION 8