What was found
FLOOR PANEL 241XF UPPER SURFACE HAS PULLED STRANDS. PANEL SHOULD BE 231XF DUE TO THE FAULT DETAILS ON THIS DEFECT MENTIONING THE OPEN OF PANEL 231XF.<[01] IDENTIFIED FLOOR PANEL 231XF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 4 TABLE 4 AND BAC DWG 144A5810 ID: 0126. DAMAGE TO UPPER SURFACE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. FLOOR PANEL DAMAGE IS BEYOND ECONOMICAL REPAIR AND MAY BE REPLACED IAW SRM 53-00-50-2R-0 PARAGRAPH 1.A NOTE.<BR><BR>ROUGH CUT FLOOR PANEL AND LOCATED INSERT HOLES USING BMS4-17 TY6 LOT#1526676-1 IAW SRM 53-00-50-2R-0 PARAGRAPH 1.A NOTE; AND PARAGRAPH 4.A TABLE 204; AND PARAGRAPH 5.S(1)(A-D).;[02] INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K-1 AND CURED USING THERMOMETER ID: ATS2208 CAL DUE: 10/2023. APPLIED TAPE BMS8-283 LOT# OCN056838; AND PART MARKED FLOOR PANEL AS REQUIRED IAW SRM 53-00-50-2R-0 PARAGRAPH 5.S(1)(D-H); AND BAC DWG 1144A5810 ID: 0126.;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE;[04] PANEL WAS REPLACED WITH NEW PANEL FABRICATED FROM RAW STOCK IAW SRM 53-00-50-2R-0 AND DRAWING 1445810.<BR><BR>UPLOADED CURE SHEET.<BR><BR>JOB COMPLETE.;[05] VERIFIED CORRECTIVE ACTION 4;[06] CORRECTION FOR LINE 2; ' BAC DWG 1144A5810' SHOULD READ ' BAC DWG 144A5810'.;[07] VERIFIED CORRECTION TO CORRECTIVE ACTION 2