What was found
FLOOR PANEL 242DF UPPER SURFACE HAS PULLED STRANDS.<[01] PANEL DAMAGE TO MARKED AREA WITH PULLED STRANDS EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR. 4. F.<BR><BR>FABRICATING NEW FLOORBOARD IAW SRM 53-00-50-2R-0 PAR. 1. A. NOTE:<BR><BR>FABRICATED NEW FLOORBOARD USING BMS4-23 TY II LOT# 1525675-1; SANDED EDGES; LOCATED ALL INSERT HOLES AND CLEANED AND PART MARKED FOLLOWING DWG DOC:144A5810 ID: 0003 IAW SRM 53-00-50-2R-0 PAR. 4.A.(2) TABLE 204 AND PAR. 5. E. (1)<BR><BR>INSTALLED ALL INSERTS USING BMS5-107 EPIBOND 420 LOT# AK2KP8383K-1 AND CURED UNDER HEAT LAMP MONITORED BY THERMOMETER ID: ATS2209 CAL/DUE: 10/2023 AND CLEANED IAW SRM 53-00-50-2R-0 PAR. 5. S. (1) (D) - (H);[02] UPLOADED CURE SHEET. JOB COMPLETE.;[03] VERIFIED CORRECTIVE ACTION ITEMS 1-2 AND MEASUREMENTS TABLE.