What was found
CRACK SUPPORT ANGLE LOCATED BS 695 AND RBL 24.75 CENTER SECTION 2023-330356<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 25-JAN-24; TEMPERATURE PID CTRL P/N: 48VFL11; S/N: AE-31448; DUE DATE: 14-JUN-23.;[02] REPLACED SUPPORT ANGLE LOCATED BS 695 AND RBL 24.75 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 273A9110 SHEET 6 REV A. SEE INDIVIDUAL SIGNOFFS BELOW.;[03] REPLACED SUPPORT ANGLE LOCATED BS 695 AND RBL 24.75 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 273A9110 SHEET 6 REV A. SEE INDIVIDUAL SIGNOFFS BELOW RII CERTIFIED