What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 AND LBL 24.75 CENTER SECTION 2023-361016<[01] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811019 DUE DATE: 25-JAN-24. TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE: 25-JAN-24.;[02] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 695 AND LBL 24.75 CENTER SECTION IAW B737-700 SRM 51-10-02 Ï¿½TEM 9; SRM 51-40-02 AND DWG 273A9110; SHEET 6; REV: A <BR>SEE INDIVIDUAL SIGN OFF BELOW;[03] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 695 AND LBL 24.75 CENTER SECTION IAW B737-700 SRM 51-10-02 Ï¿½TEM 9; SRM 51-40-02 AND DWG 273A9110; SHEET 6; REV: A <BR>SEE INDIVIDUAL SIGN OFF BELOW. AS RII.