As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 AND BL 0 CENTER SECTION 2023-361015<[01] REPLACED ANGLE OF FLOOR STRUCTURE AND FASTENERS LOCATED ON BS695 AND BL 0 AT CENTER SECTION IAW B737-700 SRM 51-40-02 AND DWG 273A9110 SHEET 6 REV A;[02] REPLACED ANGLE OF FLOOR STRUCTURE AND FASTENERS LOCATED ON BS695 AND BL 0 AT CENTER SECTION IAW B737-700 SRM 51-40-02 AND DWG 273A9110 SHEET 6 REV A RII