What was found
CUSTOMER REQUEST CRACK ON STR 16L LOCATED BS 291.5 AT FWD GALLEY AREA 2023-361084<[01] ULTRASONIC EQUIPMENT USED P/N: 45MG; S/N: 221860711 AND DUE DATE: 07-NOV-23.;[02] TOOL USED DIGITAL CALIPER P/N: 500-197-30; S/N: A21042066; DUE DATE: 30-JUN-23.;[03] TOOL USED; EDDY CURRENT FLAW DETECTOR PN: NORTEC 600D; SN: 220272512; CAL DUE DATE: 17-DEC-23;[04] PERFORMED PERMANENT REPAIR LOCATED BS 291.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02;SRM 53-00-03-2R-1 REPAIR 1 FIGURE 206 SHEET 2 AND DWG 141A3120 SHEET 37 REV A<BR>SEE INDIVIDUAL SIGN OFF BELOW;[05] PERFORMED PERMANENT REPAIR LOCATED BS 291.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02;SRM 53-00-03-2R-1 REPAIR 1 FIGURE 206 SHEET 2 AND DWG 141A3120 SHEET 37 REV A <BR>SEE INDIVIDUAL SIGN OFF BELOW AS RII