What was found
RT WING T/E PANEL 661BB AFT FASTENER HOLES ARE CRACKING AROUND EDGES<[01] IDENTIFIED PANEL 661BB IAW SRM 57-51-01-0I-1 FIGURE 3; TABLE 2; ITEM (9).<BR><BR>PANEL IS BEYOND ALLOWABLE DAMAGE LIMITS IAW SRM 57-51-01-1A-1 PARA 4 B (5)(A).<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 51-70-04-2R-9 AS DIRECTED BY SRM 57-51-01-2R-1 PARA 4 B (2) TABLE 202.<BR><BR>REMOVED DAMAGE TO (52EA) FASTENER HOLES ALL TO A MEASURE OF .5'DIA; CLEANED; WITH NO CONTAMINATION NOTED IAW 51-70-04-2R-9 PARA 4 A-C.;[08] USING BMS9-3 STYLE 1581 GLASS LOT 1522395-2 & BMS8-301/EA9390 RESIN LOT JH2EAA8895. FABRICATE D REPAIR PLIES; THEN LAID UP THE REPAIR; VACUUM BAGGED; LEAK CHECKED THEN SET TO CURE IAW SRM 51-70-04-2R-9 PARA 4. STEPS J; K & L. REF CAL TOOL HOT BONDER ID ATS2802 CAL DUE 10/2023.;[09] REPAIR PLIES CURED IAW SRM 51-70-04-2R-9 PARA 4. M. PER GENERAL REPAIR SECTION SRM 51-70-04-2R-0 PARA 4. N. (2). FIGURE 214. PAGE 39.<BR>REF CAL TOOL HOT BONDER ID ATS2802 CAL DUE 10/2023.<BR>REQUEST POST REPAIR EXAMINATION IAW SRM 51-70-04-2R-9 PARA 4. O