What was found
DOT 075-31 AFT CARGO FLOOR PANEL 140BF CORROSION AROUND EDGES OF PANEL.<[01] EVALUATED CORROSION ON FLOOR PANEL 140BF; FOUND TO BE GREATER THAN 3' IN LEGTH. MEASURED WITH STEEL RULE. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 STEP 5. A. (B) 1);[02] VERIFIED MATERIAL TO FAB NEW PANEL AS 2024T-3 .071' IAW AMM 50-10-04-00-801 STEP 3.A.(2) AND DWG 453A2610-58 REV D ATAG A129386;[03] VERIFIED STEPS 1 & 2;[04] BEGAN FABRICATION OF PANEL 140BF IAW AMM 50-10-04-00-801 STEP 3.A.(2);[05] VERIFIED ITEM 4<BR><BR>OK TO TREAT AND PRIME;[06] COMPLETED FAB OF FLOOR PANEL 140B FIAW AMM 50-10-04-00-801 STEP 3.A.(2);[07] VERIFIED ITEM 6;[08] APPLIED FINISHES TO FLOOR PANEL 140BF IAW AMM50-10-04;[09] VERIFIED STEP 8.<BR>AUDIT COMPLETE.