What was found
AFT CABIN FLOOR PANEL 241ADF HAS A BROKEN AFT O/B CORNER<[01] IDENTIFIED PANEL IAW SRM 53-00-50-0I-1 FIGURE 6. DAMAGE TO THE PANEL IS BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.B AND WILL BE REPAIRED IAW SRM 53-00-50-2R-4. REMOVED AN APPROX. 1.7'X.8' AREA OF DAMGED BAGSIDE PLIES AND PARTIAL CORE AND CLEANED REPAIR AREA WITH NO DISBOND OR CONTAMINATION NOTED; WORK PERFORMED IAW SRM 53-00-50-2R-4 PARAGRAPH 3.A-E.;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-4.;[03] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1 AND 2.<BR><BR>VERIFIED MEASUREMENTS TABLE.;[04] POTTED REPAIR AREA WITH BMS5-28 TYPE 19 LOT AK2LP8414K AND SET TO CURE WITH HOTBONDER ID: NCX000523 DUE: 06/2023 ALL IAW SRM 53-00-50-2R-4 PARAGRAPH 3.F-G.;[05] CURED POTTING COMPOUND; SANDED TO CONTOUR.<BR><BR>REMOVED 3 EA THROUGH INSERTS TO FACILITATE MAINTENANCE.<BR><BR>FABRICATED REPAIR PLIES FROM BMS 9-3 TY H2 LOT#1522395-2 IAW SRM 53-00-50-2R-4.PARA 3.B; G-K.(1).<BR>OK TO INSTALL.;[06] VERIFIED CORRECTIVE ACTIONS 4 AND 5<BR><BR>OK TO INSTALL REPAIR PLIES;[07] INSTALLED REPAIR PLIES USING RESIN BMS 8-201 TY 4 LOT#1527294-1 USING SCALE ID:ATS2276 CAL DUE:04/2024.<BR>VACUUM BAGGED; CHECKED FOR LEAKS USING VACUUM GAUGE ID:E11543 CAL DUE:09/2023.<BR>LEAK CHECK GOOD IAW SRM 53-00-50-2R-4.PARA 3.K.(1); L.(1).;[08] VERIFIED CORRECTIVE ACTION 7;[09] CURED REPAIR PLIES USING HEAT RAMP AND THERMOMETER ID:ATS2402 CAL DUE:07/2023 IAW SRM 53-00-50-2R-4.PARA 3.L.(1); M.(1).