What was found
AFT CARGO COMPARTMENT LEFT FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT STA: 727+6; 727E+6;747; 747+2; 747+10; 747+14; 767; 767+3; 767+4.5; 787. WL 156: LBL 20 TO 24<[01] REMOVED CORROSION ABOUT 1' X 1' AT <BR>STA 727+6 0.005'(OUT OF LIMIT)<BR>STA 727E+6 0.002'<BR>STA 747 0.003'<BR>STA 747+2 0.003'<BR>STA 747+10 0.006'(OUT OF LIMIT)<BR>STA 747+14 0.003'<BR>STA 767 0.003'<BR>STA 767+3 0.006'(OUT OF LIMIT)<BR>STA 767+4.5 0.002'<BR>STA 787 0.005'(OUT OF LIMIT)<BR>IAW SRM 51-10-02-0G-0;06] LOCATED AND DRILLED; COUNTERSANK REPLACEMENT ACB L/H FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05; SRM 51-40-06; SRM51-40-08; DWG 146A7502 ID0027 REV-.;[07] LOCATED AND DRILLED NEW SPLICE AT STA 727E+10 IAW SRM 53-00-53-2R-6;[08] APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01-0G-0 AND SOPM 20-41-02<BR><BR>OK TO INSTALL NEW SPLICE TO NEW FLOOR TO SIDEWALL SUPPORT;[10] INSTALLED NEW SPLICE AT FLOOR TO SIDEWALL SUPPORT IAW SRM 53-00-53-2R-6;[18] INSTALLED NEW AFT CARGO COMPARTMETNT LEFT FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0 AND DWG 146A7500 ID:0073 REV:-;[19] VERIFIED CORRECTIVE ACTION STEP 18.;[20] VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.