What was found
CORROSION ON FWD ENTRY DOOR MOPSILL BS 300-312; LBL 65; WL 208.<[01] VERIFIED APPLICABILITY OF SRM 53-10-15-1A-1; REMOVED CORROSION OF FWD ENTRY DOOR MOPSILL BS 300-312; LBL 65; WL 208 AND FOUND OUT OF LIMITS; MATERIAL THICKNESS 0.090' REMOVED MATERIAL 0.020' REMAINING THICKNESS 0.070' IAW SRM 53-10-15-1A-1; 53-10-15-0I-1 TOOL USED ATS 1225 DUE DATE 08/2023 AND ATS2738 DUE DATE 04/2024.;[02] REMOVED FWD ENTRY DOOR MOPSILL BS 300-312; LBL 65; WL 208 IAW SRM 51-40-02-0G-0.;[03] CORRECTION ON DAMAGE LOCATION: VERIFIED APPLICABILITY OF SRM 53-10-15-1A-1; REMOVED CORROSION OF FWD ENTRY DOOR MOPSILL BS 300-312; LBL 58; WL 208 AND FOUND OUT OF LIMITS; MATERIAL THICKNESS 0.090' REMOVED MATERIAL 0.020' REMAINING THICKNESS 0.070' IAW SRM 53-10-15-1A-1; 53-10-15-0I-1 TOOL USED ATS 1225 DUE DATE 08/2023 AND ATS2738 DUE DATE 04/2024.;[04] VERIFIED CORRECTIVE ACTION STEPS 1-3.;[05] LOCATED AND DRILLED NEW FWD ENTRY DOOR MOPSILL I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 141A8110 OK TO INSTALL;[06] VERIFIED CORRECTION ACTION ITEM 5; OK TO INSTALL GIVEN.;[07] INSTALLED NEW FWD ENTRY DOOR MOPSILL I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 141A8110;[08] VERIFIED CORRECTION ACTION ITEM 7.;[09] VERIFIED CORRECTION ACTION ITEM 7 AND MEASUREMENT TABLE; CARD COMPLETE.