What was found
CORROSION ON STRAP AT MID CABIN BS707 LBL65 WL203.<[01] REMOVED CORROSION ON MID CABIN AT BS 707; LBL 65; WL 203; IN <BR> AN AREA OF 0.4'X1.7'IAW SRM 51-10-02-0G-0;[02] UPDATED STEP 1;[03] INSPECTED AND VERIFIED CORRECTIVE ACTION 1.;[04] COMPLETED STEPS 2;3;4.;[05] EDITED MEASUREMENT 14.;[06] COMPLETED MEASUREMENT TABLE. STRAP AT MID CABIN BS 707; LBL 65; WL 203 FOUND TO HAVE NO ALLOWABLE DAMAGE ENTRY; THEREFORE; DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 51-10-02-0G-0.;[07] COMPLETED STEP 1.;[08] REFER TO FAULT TTG8Q00LF7SW WHERE EA 23-153-01843 WAS ADDED AS A SUBTASK.;[09] VERIFIED STEPS 1 COMPLETE AND MEASUREMENT TABLE; ALL STEPS COMPLETE.