What was found
CORROSION ON STRAP AT MID CABIN BS703 RBL67 WL203.<[01] REMOVED CORROSION ON MID CABIN AT BS 703; RBL 65; WL 203; IN <BR> AN AREA OF 0.5'X0.9'IAW SRM 51-10-02-0G-0;[02] REMOVED CORROSION ON MID CABIN AT BS 703; RBL 65; WL 203; IN <BR> AN AREA OF 0.5'X0.9' AND 0.5'X0.8' IAW SRM 51-10-02-0G-0;[03] UPDATED STEP 1;[04] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1 AND 2;[05] COMPLETED STEPS 2;3.;[06] EDITED MEASUREMENT 14.;[07] COMPLETED MEASUREMENT TABLE. STRAP AT MID CABIN BS 703; RBL 67; WL 203 FOUND TO HAVE NO ALLOWABLE DAMAGE ENTRY; THEREFORE DAMAGE FOUND TO BE OUT OF LIMTS PER SRM 51-10-02-0G-0.;[08] COMPLETED STEP 1.;[09] REFER TO FAULT TTG8Q00LF7SW WHERE EA 23-153-01843 WAS ADDED AS A SUBTASK.;[10] VERIFIED STEPS 1;2;3; COMPLETE.;[11] VERIFIED MEASUREMENT TABLE.