What was found
CORROSION ON WEB AT MID CABIN BS711 RBL64 WL203.<[01] REMOVED CORROSION ON MID CABIN WEB AT BS 711 RBL 64; WL 203; IN<BR> AN AREA OF 0.5'X0.8'IAW SRM 51-10-02-0G-0;[02] CORRECTED MEASUREMENT TABLE;[03] INSPECTED AND VERIFIED CORRECTIVE ACTION 1.;[04] COMPLETED STEPS 1; 2.;[05] EDITED MEASUREMENT 14.;[06] DUE TO INCORRECT MEASUREMENTS GIVEN DURING PRIOR INSPECTION.<BR>UT RE-INSPECTED BLENDED AREA IAW 737 NDTM PART 4 51-00-00 PROCEDURE 2.<BR>REMAINING MATERIAL THICKNESS IS 0.054' ADJACENT TO 0.056'. <BR>EQUIP USED: <BR>-NORTEC 600 ID: ATS1465 CAL DUE: 09/23<BR>-EPOCH 650 ID: ATS2342 CAL DUE: 07/23;[07] CORRECTION TO CORRECTIVE ACTION 6.<BR>EQUIPMENT NORTEC 600 ID: ATS1465 WAS NOT USED DURING INSPECTION.;[08] COMPLETED MEASUREMENT TABLE. WEB AT MID CABIN BS 711; RBL 64; WL 203 HAS NO ALLOWABLE DAMAGE ENTRY; THEREFORE; DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 51-10-02-0G-0.;[09] REFER TO FAULT TTG8Q00LF7SW WHERE EA 23-153-01843 WAS ADDED AS A SUBTASK.;[10] VERIFIED ALL STEPS COMPLETE; MEASUREMENT TABLE AND CORRECTION ACTION ITEM 9.