What was found
R/W T/E PANEL 661CB HAS SEVERAL PULLED FASTENER HOLE ON AFT END (MARKED)<[01] PART/MATERIAL IDENTIFIED PER SRM 57-51-01-0I-1 FIGURE 3 TABLE 3 ITEM 10.<BR>MULTIPLE PULLED FASTENER HOLES EXCEED THE ALLOWABLE LIMITS AS GIVEN IN SRM 57-51-01-1A-1 PARA 4. B. (4). REPAIR TO BE PERFORMED IAW SRM 51-70-04-2R-9 PER SRM 57-51-01-2R-1 PARA 4. C.;[02] PERFORMED DAMAGE REMOVAL & SURFACE PREPARATION STEPS AS GIVEN IN SRM 51-70-04-2R-9 PARA 4. STEPS A-C. <BR>USING BMS8-301/EA9390 RESIN LOT JH2EAA8896 & CHOPPED FIBERS IAW SRM 51-70-04-2R-0 TABLE 203. OK TO FILL.;[03] VALIDATED APPLICABILITY OF DAMAGE TO BE REPAIRED IAW SRM 51-70-04-3R-9.<BR><BR>OK TO APPLY SLURRY MIX.;[04] VERIFIED CORRECTIVE ACTIONS 1-3<BR><BR>VERIFIED MEASUREMENTS TABLE<BR><BR>VALIDATED REPAIR PER SRM 51-70-04-2R-9<BR><BR>OK TO APPLY SLURRY MIXTURE;[05] APPLIED BMS8-301/EA9390 RESIN LOT JH2EAA8896 & CHOPPED FIBERS TO DEFECTIVE FASTENER HOLES IAW SRM 51-70-04-2R-9 PARA 4 STEPS D & E. <BR>REQUIRES CURE.;[06] CURED SLURRY MIXTURE UNDER HEAT LAMP USING THERMOMETER ID:ATS2208 DUE:10/2023 IAW SRM 51-70-04-2R-9 PAR.4 F;[07] SANDED SLURRY FLUSH; CLEANED REPAIR AREA; FABRICATED REPAIR PLIES FROM BMS9-3 TYPE H2 CLASS 7 STYLE 1581 LOT 1526805-2; INSTALLED PLIES WITH BMS8-301 CLASS 1 LOT JH2EAA8895;