What was found
FWD FLOOR PANEL 221DF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED PANEL 221DF MATERIAL IAW SRM 53-00-50-0I-1 FIG 2; TABLE 2.<BR><BR>CLEANED PANEL REPAIR AREA IAW SRM 53-00-50-2R-0 PARA 5. A. (1).<BR><BR>FOUND DAMAGE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F.<BR><BR>REPAIR TO BE ACCOMPLISHED IAW SRM 53-00-50-2R-1.<BR><BR>REMOVED (2 EA.) DRAIN FITTING ASSEMBLIES; (29 EA.) THROUGH INSERTS AND (8 EA.) BLIND INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3.B AND BOEING DRAWING: 141A5810 ID: 0235. WILL REQUIRE REINSTALLATION UPON REPAIR COMPLETION.<BR><BR>REMOVED DAMAGED PLIES AND PREVIOUS REPAIRS MEASURING 46' X 32' ON UPPER SKIN; THEN CLEANED. ALL IAW SRM 53-00-50-2R-1 PARA 3. A. AND C. - F. WITH NO MOISTURE OR CONTAMINATION NOTED.<BR><BR>OK TO POT EXPOSED CORE AREA.;[02] VALIDATED REPAIR PER SRM 53-00-50-2R-1;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE<BR><BR>VALIDATED REPAIR PER SRM 53-00-50-2R-1 <BR><BR>OK TO POT EXPOSED CORE AREA;[04] APPLIED POTTING COMPOUND BMS 5-28 TY19; LOT # 1528833-1 TO OPEN CORE AREA ON UPPER SURFACE IAW SRM 53-00-50-2R-1 PARA 3. G.;[05] CURED POTTING; SANDED FLUSH; CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARAGRAPH 3.H-J.;[06] USED THERMOMETER ID: ATS2209 DUE: 10/20223 IN ITEM 5.;[07] FABRICATED REPAIR PLIES USING BMS 9-3 TY H2 LOT#1526805-2 IAW SRM 53-00-50-2R-1. PARA 3. K. (1) (A).<BR><BR>OK TO INSTALL REPAIR PLIES.;