What was found
FWD FLOOR PANEL 222AF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED PANEL 222AF IAW SRM 53-00-50-0I-1.<BR>FOUND DAMAGE ON UPPER SURFACE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1.PARA 4.F.<BR>DAMAGE SHOULD BE REPAIRED PER SRM 53-00-50-2R-1.<BR><BR>REMOVED ALL INSERTS TO FACILITATE MAINTENANCE.<BR>REMOVED DAMAGED PLIES AND LOOSE PIECE OF CORE ON APPROX. 41'X24' DAMAGED AREA IAW SRM 53-00-50-2R-1.PARA 3.A-F.<BR>OK TO POT EXPOSED CORE.;[02] VALIDATED REPAIR PER SRM 53-00-50-2R-1;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE<BR><BR>VALIDATED REPAIR PER SRM 53-00-50-2R-1 <BR><BR>OK TO POT EXPOSED CORE AREAS;[04] APPLIED POTTING COMPOUND BMS 5-28 TY 19 LOT#1528833-1 IAW SRM 53-00-50-2R-1.PARA 3.G;[05] CURED POTTING UNDER HEAT LAMP USING THERMOMETER ID:ATS2209 DUE:10/23; SANDED POTTING SMOOTH; CLEANED REPAIR AREA; AND FABRICATED REPAIR PLIES USING BMS 9-3 ST1581 LOT#1526805-2 IAW SRM 53-00-50-2R-1 PARA 3.H-K(1);[06] VERIFIED CORRECTIVE ACTIONS 4 & 5.<BR>OK TO INSTALL REPAIR PLIES.;[07] INSTALLED REPAIR PLIES USING BMS 8-201 TY 4 LOT#1527294-1; VACUUM BAGGED; CHECKED FOR LEAKS USING VACUUM GAUGE ID:ATS2441 CAL DUE:08/2023.<BR>LEAK CHECK GOOD IAW SRM 53-00-50-2R-1.PARA 3.K.(1); L.(1).