What was found
FWD FLOOR PANEL 222BF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 222BF IAW SRM 53-00-50-0I-1 FIGURE 2 TABLE 2 <BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 B<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1 <BR><BR>REMOVED (46EA) THROUGH INSERTS & (9EA) BLIND INSERTS TO FACILITATE REPAIR<BR>REMOVED DAMAGE IN MULTIPLE AREAS; WITH THE LARGEST MEASURING 43'X33.5'; CLEANED; WITH NO CONTAMINATION NOTED IAW SRM 53-00-50-2R-1 PAR.3 A-F<BR><BR>OK TO POT;[02] VALIDATED REPAIR PER SRM 53-00-50-2R-1;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE<BR><BR>VALIDATED REPAIR PER SRM 53-00-50-2R-1 <BR><BR>OK TO POT;[04] POTTED OPEN CORE CELLS USING BMS5-28 TY19 LOT#1528833-1 IAW SRM 53-00-50-2R-1 PAR.3 G;[05] CURED POTTING; SANDED FLUSH; CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARAGRAPH 3.H-J.;[06] USED THERMOMETER ID: ATS2209 DUE: 10/20223 IN ITEM 5.;[07] FABRICATED REPAIR PLIES FROM BMS9-3 ST1581 LOT#1526805-2 IAW SRM 53-00-50-2R-1 PAR.3 K(1)<BR><BR>OK TO INSTALL;