What was found
CRACK INDICATION FOUND ON ANGLE CLIP LOCATED ON FLOOR STRUCTURE BTW BS 291.5 AND BS296.4 STR 17R RBL 52 AT FWD GALLEY AREA. 2023-378121<[01] TOOL USED: CALIPER P/N 500-752-20 S/N B21038528 CAL. DUE DATE 20 SEP 23.;[02] REPLACED NEW ANGLE CLIP LOCATED ON FLOOR STRUCTURE BTW BS 291.5 AND BS296.4 STR 17R RBL 52 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 141A8310 SHEET 25 REV-.;[03] CORRECTED STEP 2 <BR>REPLACED NEW ANGLE CLIP LOCATED ON FLOOR STRUCTURE BTW BS 291.5 AND BS296.4 STR 17R RBL 52 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 141A8310 SHEET 25 REV-. SEE INDIVIDUAL SIGN OFF BELOW;[04] CORRECTED STEP 2 <BR>REPLACED NEW ANGLE CLIP LOCATED ON FLOOR STRUCTURE BTW BS 291.5 AND BS296.4 STR 17R RBL 52 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 141A8310 SHEET 25 REV-. RII. SEE INDIVIDUAL SIGN OFF BELOW.