What was found
*CUSTOMER WALK* EMERGENCY EXIT SIGN LIGHT BULBS OUT OVER L1 DOOR; R2 DOOR; AND BOTH FORWARD OVER WING EXISTS; JUST A FEW BULBS IN EACH.<[01] REPLACED EMERGENCY EXIT LIGHT BULBS OVER L1 DOOR; R2 DOOR AND BOTH FORWARD OVER WING EXISTS AS PER B737 AMM 33-51-01-960-801. PERFORM OPERATIONAL TEST AS PER B737 AMM 33-51-01-960-801. TEST PASSED.;[02] VERIFIED REPLACED EMERGENCY EXIT LIGHT BULBS OVER L1 DOOR; R2 DOOR AND BOTH FORWARD OVER WING EXISTS AS PER B737 AMM 33-51-01-960-801. PERFORM OPERATIONAL TEST AS PER B737 AMM 33-51-01-960-801. TEST PASSED.