What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS695 AT RBL1 CENTER SECTION 2023-378846<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24.;[02] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS695 AT RBL1 CENTER SECTION (1 EA) IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 273A9110 SHEET: 6 REV: A. SEE INDIVIDUAL SIGN OFF BELOW;[03] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS695 AT RBL1 CENTER SECTION (1 EA) IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 273A9110 SHEET: 6 REV: A. SEE INDIVIDUAL SIGN OFF BELOW<BR><BR>ITEM RII