What was found
CRACKED INTERCOSTAL AT FWD CABIN BS328+7 LBL46 WL208.<[01] REMOVED INTERCOSTAL FROM BS328-BS344 AT LBL 46 WL 208 IAW SRM 51-40-02;[02] DAMAGE FOUND AT FWD CABIN INTERCOSTAL BS 328+7; LBL-46; WL 208 FOUND TO BE OUT OF LIMIT IAW SRM 53-1-51-1A-1 DET.4B(1A); FIG 105-N;[03] LOCATED AND DRILLED NEW INTERCOSTAL P/N 141A5410-16 LOT#1530387-1 AT BS 328 TO BS 344 LBL 46 WL 208 IAW SRM 51-40-05-0G-0 AND DWG# 141A5400.OK TO INSTALL;[04] VERIFIED STEPS #1; #2; AND #3. OK TO INSTALL.;[05] INSTALLED NEW INTERCOSTAL AT BS 328 TO BS 344; LBL 46; WL 208 IAW SRM 51-40-02-0G-0 AND DWG# 141A5400.;[06] VERIFIED STEP #5;[07] VERIFIED STEP #5