What was found
CENTER CABIN FLOOR PANEL 242CF HAS A PULLED THROUGH INSERT<[01] IDENTIFIED FLOOR PANEL 242CF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 4 TABLE 4 AND BWG DWG 144A5810 ID: 0006.<BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. <BR><BR>DAMAGE TO FLOOR PANEL IS BEYOND ECONOMICAL REPAIR AND MAY BE REPLACED BY FABRICATING A NEW PANEL IAW SRM 53-00-50-2R-0 PARAGRAPH 1.A (NOTE).<BR><BR>FABRICATED NEW FLOOR PANEL BMS4-17 TYVI LOT# 1527035-1 IAW SRM 53-00-50-2R-0 PARA 4.A(2) AND BWG DWG 144A5810 ID:0006.<BR><BR>INSTALLED INSERTS USING BMS 5-107 LOT#AK2KP8383K-1 AND PART MARKED PANEL IAW BAC5085 PARA 8.4.2.2(A-G) AND BWG DWG 144A5810 ID:0006.<BR><BR>INSERTS NEED CURE.;[02] CURED BMS 5-107 FOR INSERTS MONITORING WITH THERMOMETER ID: ATS2208 CAL DUE: 10/2023 IAW BAC5085 PARA 8.4.2.2(H).;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE;[04] UPLOADED CURE SHEET. JOB COMPLETE;[05] VERIFIED CORRECTIVE ACTION 4