What was found
PANEL 193D OUTER SKIN IS DISBONDED. (MARKED)<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-40-70-0I-1 FIG 2 TABLE 2 ITEM 12.<BR>FOUND DAMAGE TO 2EA AREAS TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-40-70-1A-1 PARA 4.A(6).<BR>DAMAGE WILL BE REPAIRED IAW SRM 51-70-05-2R-2 PER SRM 53-40-70-2R-1 TABLE 201.<BR>REMOVED DAMAGED SKIN AND CORE TO 1.0' DIAMETER IN 2EA LOCATIONS; CLEANED REPAIR AREA IAW SRM 51-70-05-2R-2 PARA 4.A-C.;[02] VALIDATED APPLICABILITY OF SRM 51-70-05-2R-2.;[03] INSPECTED PANEL. OK TO CONTINUE;[04] APPLIED POTTING BMS 5-28TY7 LOT#AK2JP8360K TO OPEN CORE AND SET FOR ROOM TEMPERATURE CURE IAW SRM 51-70-05-2R-2 PARA 4.D(NOTE) AND SRM 51-70-05-2R-11 PARA 4.A-B.;[05] COMPLETED ROOM TEMPERATURE POTTING CURE; SANDED SMOOTH TO SURFACE; CLEANED REPAIR AREA; FABRICATED AND INSTALLED REPAIR PLIES USING BMS 8-79ST120 LOT#1529520-2; ADHESIVE BMS 5-129GR5 LOT#1529514-3; VACUUM BAGGED; LEAK CHECK GOOD; CURED; UNBAGGED AND LIGHTLY SANDED REPAIRS IAW SRM 51-70-05-2R-11 PARA 4.C-E AND SRM 51-70-05-2R-2 PARA 4.G-I; K.<BR><BR>REQUEST POST CURE NDI IAW SRM 51-70-05-2R-2 PARA 4.J.