What was found
CORROSION ON AFT CARGO BAY CUT-OUT FWD SHIELD FROM STA 767+2 TO STA 767+17; RBL 21 TO RBL 23; WL 156.<[01] DAMAGE FOUND AT AFT CARGO BAY FLOOR SUPPORT FWD SHIELD BS 767 TO BS 794; RBL 22; WL 156 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT STATEMENT ON SRM PARTS WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PARE.9C;[02] REMOVED ON AFT CARGO CUT OUT FWD SHIELD;IAW SRM 51-40-02.;[03] RECEIVED NEW ON AFT CARGO BAY CUT-OUT FWD SHIELD BS 767 TO BS 793 RBL23 P/N146A8127-12 PO#910166. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 146A0081;[04] VERIFIED CORRECTIVE ACTION STEP #3. OK TO CONTINUE;[05] APPLIED TOP-COAT FINISH PAINT BMS10-11 TYPE2 ON NEW SHIELD IAW AMM 51-21-73-370-804;[06] UPDATE ITEM 5: TOP-COAT FINISH PAINT BMS10-11 TYPE2 APPLICATION TIME 15-JUN-2023 03:44 UTC;[07] VERIFIED STEPS #5 AND #6;[08] APPLIED CORROSION INHIBITING COMPOUND ON NEW SHIELD IAW AMM 51-21-91-620-802.<BR>15-JUN-2023 06:07 UTC;[09] VERIFIED STEP # 8;[10] OK TO INSTALL ON ACB FWD SHIELD BS 767 TO BS 793 RBL 21-23 WL 156;[11] VERIFIED CORRECTIVE ACTION 10 OK TO INSTALL;[12] INSTALLED ON AFC FWD SHIELD FROM<BR>BS 767 TO BS 793 RBL 21-23 WL 156 IAW SRM 51-40-02<BR>AND DWG 146A0081.;[13] VERIFIED CORRECTIVE ACTION 12 <BR><BR>VERIFIED MEASUREMENT TABLE