What was found
CORROSION AFT CABIN WET AREA FLOOR SUPPORT INTERCOSTAL FASTENER'S HOLE @ RBL 27 STA 951 WL 208.1 MKD DOT<[01] REMOVED CORROSION; PERFORMED HFEC ROTOR INSPECTION; VERIFIED HFEC ROTOR INSPECTION; TREATED AND PRIMED REWORKED FASTENER HOLE; PERFORMED UT THICKNESS INSPECTION; VERIFIED UT THICKNESS INSPECTION AREA FOUND OUT OF LIMITS; REMOVED AFT CABIN WET ARE FLOOR SUPPORT INTERCOSTAL; AND INSTALLED NEW AFT CABIN WET AREA FLOOR SUPPORT INTERCOSTAL. PER SRM 51-10-02-0G-0; PER SRM 53-70-51-1A-1; PER AMM 51-21-41-370-803 AND 51-21-72-370-802; PER SRM 53-70-51-1A-1; PER SRM 51-40-02-0G-0; PER SRM 51-40-02-0G-0.;[02] VERIFIED AND INSPECTED REMOVED CORROSION AFT CABIN WET AREA FLOOR SUPPORT INTERCOSTAL FASTENER'S HOLE @ RBL 27 STA 951 WL 208.1